diff --git a/Documentation/devicetree/bindings/arm/cci.txt b/Documentation/devicetree/bindings/arm/cci.txt
deleted file mode 100644
index 9600761f2d5b..000000000000
--- a/Documentation/devicetree/bindings/arm/cci.txt
+++ /dev/null
@@ -1,224 +0,0 @@
-=======================================================
-ARM CCI cache coherent interconnect binding description
-=======================================================
-
-ARM multi-cluster systems maintain intra-cluster coherency through a
-cache coherent interconnect (CCI) that is capable of monitoring bus
-transactions and manage coherency, TLB invalidations and memory barriers.
-
-It allows snooping and distributed virtual memory message broadcast across
-clusters, through memory mapped interface, with a global control register
-space and multiple sets of interface control registers, one per slave
-interface.
-
-* CCI interconnect node
-
- Description: Describes a CCI cache coherent Interconnect component
-
- Node name must be "cci".
- Node's parent must be the root node /, and the address space visible
- through the CCI interconnect is the same as the one seen from the
- root node (ie from CPUs perspective as per DT standard).
- Every CCI node has to define the following properties:
-
- - compatible
- Usage: required
- Value type: <string>
- Definition: must contain one of the following:
- "arm,cci-400"
- "arm,cci-500"
- "arm,cci-550"
-
- - reg
- Usage: required
- Value type: Integer cells. A register entry, expressed as a pair
- of cells, containing base and size.
- Definition: A standard property. Specifies base physical
- address of CCI control registers common to all
- interfaces.
-
- - ranges:
- Usage: required
- Value type: Integer cells. An array of range entries, expressed
- as a tuple of cells, containing child address,
- parent address and the size of the region in the
- child address space.
- Definition: A standard property. Follow rules in the Devicetree
- Specification for hierarchical bus addressing. CCI
- interfaces addresses refer to the parent node
- addressing scheme to declare their register bases.
-
- CCI interconnect node can define the following child nodes:
-
- - CCI control interface nodes
-
- Node name must be "slave-if".
- Parent node must be CCI interconnect node.
-
- A CCI control interface node must contain the following
- properties:
-
- - compatible
- Usage: required
- Value type: <string>
- Definition: must be set to
- "arm,cci-400-ctrl-if"
-
- - interface-type:
- Usage: required
- Value type: <string>
- Definition: must be set to one of {"ace", "ace-lite"}
- depending on the interface type the node
- represents.
-
- - reg:
- Usage: required
- Value type: Integer cells. A register entry, expressed
- as a pair of cells, containing base and
- size.
- Definition: the base address and size of the
- corresponding interface programming
- registers.
-
- - CCI PMU node
-
- Parent node must be CCI interconnect node.
-
- A CCI pmu node must contain the following properties:
-
- - compatible
- Usage: required
- Value type: <string>
- Definition: Must contain one of:
- "arm,cci-400-pmu,r0"
- "arm,cci-400-pmu,r1"
- "arm,cci-400-pmu" - DEPRECATED, permitted only where OS has
- secure access to CCI registers
- "arm,cci-500-pmu,r0"
- "arm,cci-550-pmu,r0"
- - reg:
- Usage: required
- Value type: Integer cells. A register entry, expressed
- as a pair of cells, containing base and
- size.
- Definition: the base address and size of the
- corresponding interface programming
- registers.
-
- - interrupts:
- Usage: required
- Value type: Integer cells. Array of interrupt specifier
- entries, as defined in
- ../interrupt-controller/interrupts.txt.
- Definition: list of counter overflow interrupts, one per
- counter. The interrupts must be specified
- starting with the cycle counter overflow
- interrupt, followed by counter0 overflow
- interrupt, counter1 overflow interrupt,...
- ,counterN overflow interrupt.
-
- The CCI PMU has an interrupt signal for each
- counter. The number of interrupts must be
- equal to the number of counters.
-
-* CCI interconnect bus masters
-
- Description: masters in the device tree connected to a CCI port
- (inclusive of CPUs and their cpu nodes).
-
- A CCI interconnect bus master node must contain the following
- properties:
-
- - cci-control-port:
- Usage: required
- Value type: <phandle>
- Definition: a phandle containing the CCI control interface node
- the master is connected to.
-
-Example:
-
- cpus {
- #size-cells = <0>;
- #address-cells = <1>;
-
- CPU0: cpu@0 {
- device_type = "cpu";
- compatible = "arm,cortex-a15";
- cci-control-port = <&cci_control1>;
- reg = <0x0>;
- };
-
- CPU1: cpu@1 {
- device_type = "cpu";
- compatible = "arm,cortex-a15";
- cci-control-port = <&cci_control1>;
- reg = <0x1>;
- };
-
- CPU2: cpu@100 {
- device_type = "cpu";
- compatible = "arm,cortex-a7";
- cci-control-port = <&cci_control2>;
- reg = <0x100>;
- };
-
- CPU3: cpu@101 {
- device_type = "cpu";
- compatible = "arm,cortex-a7";
- cci-control-port = <&cci_control2>;
- reg = <0x101>;
- };
-
- };
-
- dma0: dma@3000000 {
- compatible = "arm,pl330", "arm,primecell";
- cci-control-port = <&cci_control0>;
- reg = <0x0 0x3000000 0x0 0x1000>;
- interrupts = <10>;
- #dma-cells = <1>;
- #dma-channels = <8>;
- #dma-requests = <32>;
- };
-
- cci@2c090000 {
- compatible = "arm,cci-400";
- #address-cells = <1>;
- #size-cells = <1>;
- reg = <0x0 0x2c090000 0 0x1000>;
- ranges = <0x0 0x0 0x2c090000 0x10000>;
-
- cci_control0: slave-if@1000 {
- compatible = "arm,cci-400-ctrl-if";
- interface-type = "ace-lite";
- reg = <0x1000 0x1000>;
- };
-
- cci_control1: slave-if@4000 {
- compatible = "arm,cci-400-ctrl-if";
- interface-type = "ace";
- reg = <0x4000 0x1000>;
- };
-
- cci_control2: slave-if@5000 {
- compatible = "arm,cci-400-ctrl-if";
- interface-type = "ace";
- reg = <0x5000 0x1000>;
- };
-
- pmu@9000 {
- compatible = "arm,cci-400-pmu";
- reg = <0x9000 0x5000>;
- interrupts = <0 101 4>,
- <0 102 4>,
- <0 103 4>,
- <0 104 4>,
- <0 105 4>;
- };
- };
-
-This CCI node corresponds to a CCI component whose control registers sits
-at address 0x000000002c090000.
-CCI slave interface @0x000000002c091000 is connected to dma controller dma0.
-CCI slave interface @0x000000002c094000 is connected to CPUs {CPU0, CPU1};
-CCI slave interface @0x000000002c095000 is connected to CPUs {CPU2, CPU3};