diff options
| -rw-r--r-- | fs/smb/client/cifsproto.h | 2 | ||||
| -rw-r--r-- | fs/smb/client/connect.c | 2 | ||||
| -rw-r--r-- | fs/smb/client/dfs_cache.c | 2 | ||||
| -rw-r--r-- | fs/smb/client/inode.c | 7 | ||||
| -rw-r--r-- | fs/smb/client/misc.c | 6 | ||||
| -rw-r--r-- | fs/smb/client/readdir.c | 4 |
6 files changed, 14 insertions, 9 deletions
diff --git a/fs/smb/client/cifsproto.h b/fs/smb/client/cifsproto.h index c4ababcb51a3..00168839c123 100644 --- a/fs/smb/client/cifsproto.h +++ b/fs/smb/client/cifsproto.h @@ -317,7 +317,7 @@ int generate_smb311signingkey(struct cifs_ses *ses, #ifdef CONFIG_CIFS_ALLOW_INSECURE_LEGACY #endif /* CONFIG_CIFS_ALLOW_INSECURE_LEGACY */ -void cifs_autodisable_serverino(struct cifs_sb_info *cifs_sb); +void cifs_autodisable_serverino(struct cifs_sb_info *cifs_sb, const char *reason, int rc); bool couldbe_mf_symlink(const struct cifs_fattr *fattr); int check_mf_symlink(unsigned int xid, struct cifs_tcon *tcon, struct cifs_sb_info *cifs_sb, struct cifs_fattr *fattr, diff --git a/fs/smb/client/connect.c b/fs/smb/client/connect.c index a187398fbabd..ba749ec25a59 100644 --- a/fs/smb/client/connect.c +++ b/fs/smb/client/connect.c @@ -3876,7 +3876,7 @@ int cifs_mount(struct cifs_sb_info *cifs_sb, struct smb3_fs_context *ctx) * After reconnecting to a different server, unique ids won't match anymore, so we disable * serverino. This prevents dentry revalidation to think the dentry are stale (ESTALE). */ - cifs_autodisable_serverino(cifs_sb); + cifs_autodisable_serverino(cifs_sb, "DFS failover may potentially connect to a different server, inode numbers won't match anymore", 0); /* * Force the use of prefix path to support failover on DFS paths that resolve to targets * that have different prefix paths. diff --git a/fs/smb/client/dfs_cache.c b/fs/smb/client/dfs_cache.c index 44409ba44e1d..8cd93cd2f00f 100644 --- a/fs/smb/client/dfs_cache.c +++ b/fs/smb/client/dfs_cache.c @@ -1328,7 +1328,7 @@ int dfs_cache_remount_fs(struct cifs_sb_info *cifs_sb) * After reconnecting to a different server, unique ids won't match anymore, so we disable * serverino. This prevents dentry revalidation to think the dentry are stale (ESTALE). */ - cifs_autodisable_serverino(cifs_sb); + cifs_autodisable_serverino(cifs_sb, "DFS failover may potentially connect to a different server, inode numbers won't match anymore", 0); /* * Force the use of prefix path to support failover on DFS paths that resolve to targets * that have different prefix paths. diff --git a/fs/smb/client/inode.c b/fs/smb/client/inode.c index 16a3ddff060f..deed04dd9b91 100644 --- a/fs/smb/client/inode.c +++ b/fs/smb/client/inode.c @@ -1147,7 +1147,7 @@ static void cifs_set_fattr_ino(int xid, struct cifs_tcon *tcon, struct super_blo fattr->cf_uniqueid = CIFS_I(*inode)->uniqueid; else { fattr->cf_uniqueid = iunique(sb, ROOT_I); - cifs_autodisable_serverino(cifs_sb); + cifs_autodisable_serverino(cifs_sb, "Cannot retrieve inode number via get_srv_inum", rc); } return; } @@ -1644,7 +1644,7 @@ retry_iget5_locked: fattr->cf_flags &= ~CIFS_FATTR_INO_COLLISION; if (inode_has_hashed_dentries(inode)) { - cifs_autodisable_serverino(CIFS_SB(sb)); + cifs_autodisable_serverino(CIFS_SB(sb), "Inode number collision detected", 0); iput(inode); fattr->cf_uniqueid = iunique(sb, ROOT_I); goto retry_iget5_locked; @@ -1710,8 +1710,9 @@ struct inode *cifs_root_iget(struct super_block *sb) iget_root: if (!rc) { if (fattr.cf_flags & CIFS_FATTR_JUNCTION) { + cifs_dbg(VFS, "Removing junction mark and disabling 'serverino' to prevent inode collisions\n"); fattr.cf_flags &= ~CIFS_FATTR_JUNCTION; - cifs_autodisable_serverino(cifs_sb); + cifs_autodisable_serverino(cifs_sb, "Cannot retrieve attributes for junction point", rc); } inode = cifs_iget(sb, &fattr); } diff --git a/fs/smb/client/misc.c b/fs/smb/client/misc.c index ee1728eec8aa..e4bac2a0b85d 100644 --- a/fs/smb/client/misc.c +++ b/fs/smb/client/misc.c @@ -278,7 +278,7 @@ dump_smb(void *buf, int smb_buf_length) } void -cifs_autodisable_serverino(struct cifs_sb_info *cifs_sb) +cifs_autodisable_serverino(struct cifs_sb_info *cifs_sb, const char *reason, int rc) { unsigned int sbflags = cifs_sb_flags(cifs_sb); @@ -290,6 +290,10 @@ cifs_autodisable_serverino(struct cifs_sb_info *cifs_sb) atomic_andnot(CIFS_MOUNT_SERVER_INUM, &cifs_sb->mnt_cifs_flags); cifs_sb->mnt_cifs_serverino_autodisabled = true; + if (rc) + cifs_dbg(VFS, "%s: %d\n", reason, rc); + else + cifs_dbg(VFS, "%s\n", reason); cifs_dbg(VFS, "Autodisabling the use of server inode numbers on %s\n", tcon ? tcon->tree_name : "new server"); cifs_dbg(VFS, "The server doesn't seem to support them properly or the files might be on different servers (DFS)\n"); diff --git a/fs/smb/client/readdir.c b/fs/smb/client/readdir.c index a50c86bbe60f..ee5996e6d7d8 100644 --- a/fs/smb/client/readdir.c +++ b/fs/smb/client/readdir.c @@ -415,7 +415,7 @@ ffirst_retry: if (rc == 0) { cifsFile->invalidHandle = false; } else if (rc == -EOPNOTSUPP && (sbflags & CIFS_MOUNT_SERVER_INUM)) { - cifs_autodisable_serverino(cifs_sb); + cifs_autodisable_serverino(cifs_sb, "Cannot retrieve inode number via query_dir_first", rc); goto ffirst_retry; } error_exit: @@ -1029,7 +1029,7 @@ static int cifs_filldir(char *find_entry, struct file *file, fattr.cf_uniqueid = de.ino; } else { fattr.cf_uniqueid = iunique(sb, ROOT_I); - cifs_autodisable_serverino(cifs_sb); + cifs_autodisable_serverino(cifs_sb, "Cannot retrieve inode number from readdir", 0); } if ((sbflags & CIFS_MOUNT_MF_SYMLINKS) && couldbe_mf_symlink(&fattr)) |
