authorManaf Meethalavalappu Pallikunhi <manaf.pallikunhi@oss.qualcomm.com>2026-09-22 17:49:02 +0530
committerRafael J. Wysocki <rafael.j.wysocki@intel.com>2026-09-22 21:16:11 +0200
commitec0d89150a9381d591344a9f6f5428655c227a7f (patch)
tree6457ed2ad02dc0ea1650a078b5355bba5b86a490 /tools/perf/scripts/python/flamegraph.py
parent93f51579e7df248780214094418f205253383cc5 (diff)
downloadlinux-next-ec0d89150a9381d591344a9f6f5428655c227a7f.tar.gz
linux-next-ec0d89150a9381d591344a9f6f5428655c227a7f.zip
thermal: gov_step_wise: Fix stale mitigation vote with non-zero lower bounds
When two or more thermal zones bind to a common cooling device and one zone uses a non-zero instance->lower value, there is a bug where the instance holds a stale mitigation vote even after its trip is cleared. Problem scenario: - thermal-zone1: Trip at 50°C, cooling-map with lower=0 - thermal-zone2: Trip at 55°C, cooling-map with lower=2 - Both zones share the same cooling device (e.g., CPU) Issue flow: 1. Both trips trigger, zone1 requests state 5, zone2 also mitigates 2. Zone2 trip clears (temp < 53°C due to hysteresis) 3. When throttle=false and trend=THERMAL_TREND_DROPPING: - Current code checks: if (cur_state <= instance->lower) return THERMAL_NO_TARGET - Since cur_state (5) > instance->lower (2), it returns instance->lower (2) - This is the BUG where it returns instance->lower even though trip is cleared 4. Zone2's passive polling stops (tz->passive reaches 0) - no more updates for zone2 5. Zone2's stale vote of 2 persists indefinitely 6. Even when zone1 wants to reduce cooling to state, the cooling device cannot go below state 2 due to zone2's stale vote When a trip is cleared (throttle == false), always return THERMAL_NO_TARGET instead of instance->lower. Remove the unnecessary check comparing cur_state with instance->lower. Since passive polling is already deactivated when the trip is cleared, the instance should always be deactivated regardless of its current cooling state. This ensures that instances with non-zero lower bounds do not retain stale mitigation votes after their trips are cleared. Fixes: 042a3d80f118 ("thermal: core: Move passive polling management to the core") Signed-off-by: Manaf Meethalavalappu Pallikunhi <manaf.pallikunhi@oss.qualcomm.com> Link: https://patch.msgid.link/20260922-step_wise_multi_zone_stale_vote_fix-v1-1-789f68dab229@oss.qualcomm.com Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Diffstat (limited to 'tools/perf/scripts/python/flamegraph.py')
0 files changed, 0 insertions, 0 deletions