Age | Commit message (Collapse) | Author |
|
ACPI INT3403 device object can be used to retrieve temperature date
from temperature sensors present in the system, and to expose
device' performance control.
The previous INT3403 thermal driver supports temperature reporting only,
thus remove it and introduce this new & enhanced one.
Signed-off-by: Lan Tianyu <tianyu.lan@intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
|
|
The ACPI object definition can contain passive and critical
trip temperature. Export them via thermal sysfs.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
|
|
Thermal hysteresis represents a temperature difference.
But the original code treats it as a temperature value,
Convert it from tenths of degree Kelvin to Milli-Celsius
by deducing 273200. This is not right.
Kelvin and Celsius have same degree size. From temperature
difference view, the conversion between tenths of degree
Kelvin unit and Milli-Celsius unit is just to multiply 100.
Signed-off-by: Lan Tianyu <tianyu.lan@intel.com>
Acked-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
|
|
The ACPI INT3403 device objects present on some systems can be used to retrieve
temperature data from thermal sensors. Add a driver registering each INT3403
device object as a thermal zone device and exposing its _TMP, PATx and GTSH
method via the standard thermal control interface under /sys/class/thermal/.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
|