authorLoic Poulain <loic.poulain@linaro.org>2018-04-26 13:13:26 +0200
committerMarcel Holtmann <marcel@holtmann.org>2018-05-18 06:37:52 +0200
commitd6ee6ad774a986d4faaa794a0980e7c50ed359c6 (patch)
treeaf9db18d67dbbc4c8d7188ea26d641d70189e9c8 /net/bluetooth
parentd36dfb3e9b990b45bb812fd144b19737649a69ba (diff)
downloadlwn-d6ee6ad774a986d4faaa794a0980e7c50ed359c6.tar.gz
lwn-d6ee6ad774a986d4faaa794a0980e7c50ed359c6.zip
Bluetooth: Add __hci_cmd_send function
This function allows to send a HCI command without expecting any controller event/response in return. This is allowed for vendor- specific commands only. Signed-off-by: Loic Poulain <loic.poulain@linaro.org> Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Diffstat (limited to 'net/bluetooth')
-rw-r--r--net/bluetooth/hci_core.c31
1 files changed, 31 insertions, 0 deletions
diff --git a/net/bluetooth/hci_core.c b/net/bluetooth/hci_core.c
index 40d260f2bea5..b0ee9edaae35 100644
--- a/net/bluetooth/hci_core.c
+++ b/net/bluetooth/hci_core.c
@@ -3422,6 +3422,37 @@ int hci_send_cmd(struct hci_dev *hdev, __u16 opcode, __u32 plen,
return 0;
}
+int __hci_cmd_send(struct hci_dev *hdev, u16 opcode, u32 plen,
+ const void *param)
+{
+ struct sk_buff *skb;
+
+ if (hci_opcode_ogf(opcode) != 0x3f) {
+ /* A controller receiving a command shall respond with either
+ * a Command Status Event or a Command Complete Event.
+ * Therefore, all standard HCI commands must be sent via the
+ * standard API, using hci_send_cmd or hci_cmd_sync helpers.
+ * Some vendors do not comply with this rule for vendor-specific
+ * commands and do not return any event. We want to support
+ * unresponded commands for such cases only.
+ */
+ bt_dev_err(hdev, "unresponded command not supported");
+ return -EINVAL;
+ }
+
+ skb = hci_prepare_cmd(hdev, opcode, plen, param);
+ if (!skb) {
+ bt_dev_err(hdev, "no memory for command (opcode 0x%4.4x)",
+ opcode);
+ return -ENOMEM;
+ }
+
+ hci_send_frame(hdev, skb);
+
+ return 0;
+}
+EXPORT_SYMBOL(__hci_cmd_send);
+
/* Get data from the previously sent command */
void *hci_sent_cmd_data(struct hci_dev *hdev, __u16 opcode)
{