diff options
author | Ian Kent <raven@themaw.net> | 2023-11-20 06:53:19 +0800 |
---|---|---|
committer | Christian Brauner <brauner@kernel.org> | 2023-11-20 14:56:36 +0100 |
commit | 66917f85db6002ed09cd24186258892fcfca64b6 (patch) | |
tree | 29d6891850fa0f3582a58604a0c90ccd6a64e632 | |
parent | fe2c34bab6d46469ad3095955dc37e984dc24e38 (diff) | |
download | lwn-66917f85db6002ed09cd24186258892fcfca64b6.tar.gz lwn-66917f85db6002ed09cd24186258892fcfca64b6.zip |
autofs: add: new_inode check in autofs_fill_super()
Add missing NULL check of root_inode in autofs_fill_super().
While we are at it simplify the logic by taking advantage of the VFS
cleanup procedures and get rid of the goto error handling, as suggested
by Al Viro.
Signed-off-by: Ian Kent <raven@themaw.net>
Link: https://lore.kernel.org/r/20231119225319.331156-1-raven@themaw.net
Reviewed-by: Bill O'Donnell <bodonnel@redhat.com>
Cc: Al Viro <viro@zeniv.linux.org.uk>
Cc: Christian Brauner <brauner@kernel.org>
Cc: Bill O'Donnell <billodo@redhat.com>
Reported-by: <syzbot+662f87a8ef490f45fa64@syzkaller.appspotmail.com>
Signed-off-by: Christian Brauner <brauner@kernel.org>
-rw-r--r-- | fs/autofs/inode.c | 56 |
1 files changed, 21 insertions, 35 deletions
diff --git a/fs/autofs/inode.c b/fs/autofs/inode.c index a5083d447a62..1f5db6863663 100644 --- a/fs/autofs/inode.c +++ b/fs/autofs/inode.c @@ -309,9 +309,7 @@ static int autofs_fill_super(struct super_block *s, struct fs_context *fc) struct autofs_fs_context *ctx = fc->fs_private; struct autofs_sb_info *sbi = s->s_fs_info; struct inode *root_inode; - struct dentry *root; struct autofs_info *ino; - int ret = -ENOMEM; pr_debug("starting up, sbi = %p\n", sbi); @@ -328,56 +326,44 @@ static int autofs_fill_super(struct super_block *s, struct fs_context *fc) */ ino = autofs_new_ino(sbi); if (!ino) - goto fail; + return -ENOMEM; root_inode = autofs_get_inode(s, S_IFDIR | 0755); + if (!root_inode) + return -ENOMEM; + root_inode->i_uid = ctx->uid; root_inode->i_gid = ctx->gid; + root_inode->i_fop = &autofs_root_operations; + root_inode->i_op = &autofs_dir_inode_operations; - root = d_make_root(root_inode); - if (!root) - goto fail_ino; - - root->d_fsdata = ino; + s->s_root = d_make_root(root_inode); + if (unlikely(!s->s_root)) { + autofs_free_ino(ino); + return -ENOMEM; + } + s->s_root->d_fsdata = ino; if (ctx->pgrp_set) { sbi->oz_pgrp = find_get_pid(ctx->pgrp); - if (!sbi->oz_pgrp) { - ret = invalf(fc, "Could not find process group %d", - ctx->pgrp); - goto fail_dput; - } - } else { + if (!sbi->oz_pgrp) + return invalf(fc, "Could not find process group %d", + ctx->pgrp); + } else sbi->oz_pgrp = get_task_pid(current, PIDTYPE_PGID); - } if (autofs_type_trigger(sbi->type)) - __managed_dentry_set_managed(root); - - root_inode->i_fop = &autofs_root_operations; - root_inode->i_op = &autofs_dir_inode_operations; + /* s->s_root won't be contended so there's little to + * be gained by not taking the d_lock when setting + * d_flags, even when a lot mounts are being done. + */ + managed_dentry_set_managed(s->s_root); pr_debug("pipe fd = %d, pgrp = %u\n", sbi->pipefd, pid_nr(sbi->oz_pgrp)); sbi->flags &= ~AUTOFS_SBI_CATATONIC; - - /* - * Success! Install the root dentry now to indicate completion. - */ - s->s_root = root; return 0; - - /* - * Failure ... clean up. - */ -fail_dput: - dput(root); - goto fail; -fail_ino: - autofs_free_ino(ino); -fail: - return ret; } /* |