summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorLeo Yan <leo.yan@linaro.org>2016-03-29 19:23:32 +0800
committerEduardo Valentin <edubezval@gmail.com>2016-04-27 15:54:01 -0700
commit5fdfc48bb0da2aa8a912024a6ecca06486eb9141 (patch)
treedfde889af6cfa191cdd388aa7eb7ddc07ed4dc70
parent913f201083c81cf021f050d041352ac854c4b526 (diff)
downloadlwn-5fdfc48bb0da2aa8a912024a6ecca06486eb9141.tar.gz
lwn-5fdfc48bb0da2aa8a912024a6ecca06486eb9141.zip
thermal: hisilicon: increase temperature resolution
When calculate temperature, old code firstly do division and then convert to "millicelsius" unit. This will lose resolution and only can read back temperature with "Celsius" unit. So firstly scale step value to "millicelsius" and then do division, so finally we can increase resolution for temperature value. Also refine the calculation from temperature value to step value. Signed-off-by: Leo Yan <leo.yan@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
-rw-r--r--drivers/thermal/hisi_thermal.c4
1 files changed, 2 insertions, 2 deletions
diff --git a/drivers/thermal/hisi_thermal.c b/drivers/thermal/hisi_thermal.c
index 36d07295f8e3..5e820b541506 100644
--- a/drivers/thermal/hisi_thermal.c
+++ b/drivers/thermal/hisi_thermal.c
@@ -68,12 +68,12 @@ static inline int _step_to_temp(int step)
* Every step equals (1 * 200) / 255 celsius, and finally
* need convert to millicelsius.
*/
- return (HISI_TEMP_BASE + (step * 200 / 255)) * 1000;
+ return (HISI_TEMP_BASE * 1000 + (step * 200000 / 255));
}
static inline long _temp_to_step(long temp)
{
- return ((temp / 1000 - HISI_TEMP_BASE) * 255 / 200);
+ return ((temp - HISI_TEMP_BASE * 1000) * 255) / 200000;
}
static long hisi_thermal_get_sensor_temp(struct hisi_thermal_data *data,