summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorDamien Le Moal <damien.lemoal@opensource.wdc.com>2022-11-24 19:43:30 +0900
committerDamien Le Moal <damien.lemoal@opensource.wdc.com>2023-01-23 09:25:51 +0900
commit34422914dc00b291d1c47dbdabe93b154c2f2b25 (patch)
treecfdee6d1827c4ae351743d38e4086457958fd96b
parent46a9c526eef7fb68a00321e2a9591ce5276ae92b (diff)
downloadlwn-34422914dc00b291d1c47dbdabe93b154c2f2b25.tar.gz
lwn-34422914dc00b291d1c47dbdabe93b154c2f2b25.zip
zonefs: Reduce struct zonefs_inode_info size
Instead of using the i_ztype field in struct zonefs_inode_info to indicate the zone type of an inode, introduce the new inode flag ZONEFS_ZONE_CNV to be set in the i_flags field of struct zonefs_inode_info to identify conventional zones. If this flag is not set, the zone of an inode is considered to be a sequential zone. The helpers zonefs_zone_is_cnv(), zonefs_zone_is_seq(), zonefs_inode_is_cnv() and zonefs_inode_is_seq() are introduced to simplify testing the zone type of a struct zonefs_inode_info and of a struct inode. Signed-off-by: Damien Le Moal <damien.lemoal@opensource.wdc.com> Reviewed-by: Johannes Thumshirn <johannes.thumshirn@wdc.com>
-rw-r--r--fs/zonefs/file.c35
-rw-r--r--fs/zonefs/super.c12
-rw-r--r--fs/zonefs/zonefs.h24
3 files changed, 42 insertions, 29 deletions
diff --git a/fs/zonefs/file.c b/fs/zonefs/file.c
index ece0f3959b6d..64873d31d75d 100644
--- a/fs/zonefs/file.c
+++ b/fs/zonefs/file.c
@@ -77,8 +77,7 @@ static int zonefs_write_iomap_begin(struct inode *inode, loff_t offset,
* checked when writes are issued, so warn if we see a page writeback
* operation.
*/
- if (WARN_ON_ONCE(zi->i_ztype == ZONEFS_ZTYPE_SEQ &&
- !(flags & IOMAP_DIRECT)))
+ if (WARN_ON_ONCE(zonefs_zone_is_seq(zi) && !(flags & IOMAP_DIRECT)))
return -EIO;
/*
@@ -128,7 +127,7 @@ static int zonefs_write_map_blocks(struct iomap_writepage_ctx *wpc,
{
struct zonefs_inode_info *zi = ZONEFS_I(inode);
- if (WARN_ON_ONCE(zi->i_ztype != ZONEFS_ZTYPE_CNV))
+ if (WARN_ON_ONCE(zonefs_zone_is_seq(zi)))
return -EIO;
if (WARN_ON_ONCE(offset >= i_size_read(inode)))
return -EIO;
@@ -158,9 +157,8 @@ static int zonefs_swap_activate(struct swap_info_struct *sis,
struct file *swap_file, sector_t *span)
{
struct inode *inode = file_inode(swap_file);
- struct zonefs_inode_info *zi = ZONEFS_I(inode);
- if (zi->i_ztype != ZONEFS_ZTYPE_CNV) {
+ if (zonefs_inode_is_seq(inode)) {
zonefs_err(inode->i_sb,
"swap file: not a conventional zone file\n");
return -EINVAL;
@@ -196,7 +194,7 @@ int zonefs_file_truncate(struct inode *inode, loff_t isize)
* only down to a 0 size, which is equivalent to a zone reset, and to
* the maximum file size, which is equivalent to a zone finish.
*/
- if (zi->i_ztype != ZONEFS_ZTYPE_SEQ)
+ if (!zonefs_zone_is_seq(zi))
return -EPERM;
if (!isize)
@@ -266,7 +264,7 @@ static int zonefs_file_fsync(struct file *file, loff_t start, loff_t end,
* Since only direct writes are allowed in sequential files, page cache
* flush is needed only for conventional zone files.
*/
- if (ZONEFS_I(inode)->i_ztype == ZONEFS_ZTYPE_CNV)
+ if (zonefs_inode_is_cnv(inode))
ret = file_write_and_wait_range(file, start, end);
if (!ret)
ret = blkdev_issue_flush(inode->i_sb->s_bdev);
@@ -280,7 +278,6 @@ static int zonefs_file_fsync(struct file *file, loff_t start, loff_t end,
static vm_fault_t zonefs_filemap_page_mkwrite(struct vm_fault *vmf)
{
struct inode *inode = file_inode(vmf->vma->vm_file);
- struct zonefs_inode_info *zi = ZONEFS_I(inode);
vm_fault_t ret;
if (unlikely(IS_IMMUTABLE(inode)))
@@ -290,7 +287,7 @@ static vm_fault_t zonefs_filemap_page_mkwrite(struct vm_fault *vmf)
* Sanity check: only conventional zone files can have shared
* writeable mappings.
*/
- if (WARN_ON_ONCE(zi->i_ztype != ZONEFS_ZTYPE_CNV))
+ if (zonefs_inode_is_seq(inode))
return VM_FAULT_NOPAGE;
sb_start_pagefault(inode->i_sb);
@@ -319,7 +316,7 @@ static int zonefs_file_mmap(struct file *file, struct vm_area_struct *vma)
* mappings are possible since there are no guarantees for write
* ordering between msync() and page cache writeback.
*/
- if (ZONEFS_I(file_inode(file))->i_ztype == ZONEFS_ZTYPE_SEQ &&
+ if (zonefs_inode_is_seq(file_inode(file)) &&
(vma->vm_flags & VM_SHARED) && (vma->vm_flags & VM_MAYWRITE))
return -EINVAL;
@@ -352,7 +349,7 @@ static int zonefs_file_write_dio_end_io(struct kiocb *iocb, ssize_t size,
return error;
}
- if (size && zi->i_ztype != ZONEFS_ZTYPE_CNV) {
+ if (size && zonefs_zone_is_seq(zi)) {
/*
* Note that we may be seeing completions out of order,
* but that is not a problem since a write completed
@@ -491,7 +488,7 @@ static ssize_t zonefs_write_checks(struct kiocb *iocb, struct iov_iter *from)
return -EINVAL;
if (iocb->ki_flags & IOCB_APPEND) {
- if (zi->i_ztype != ZONEFS_ZTYPE_SEQ)
+ if (zonefs_zone_is_cnv(zi))
return -EINVAL;
mutex_lock(&zi->i_truncate_mutex);
iocb->ki_pos = zi->i_wpoffset;
@@ -531,8 +528,7 @@ static ssize_t zonefs_file_dio_write(struct kiocb *iocb, struct iov_iter *from)
* as this can cause write reordering (e.g. the first aio gets EAGAIN
* on the inode lock but the second goes through but is now unaligned).
*/
- if (zi->i_ztype == ZONEFS_ZTYPE_SEQ && !sync &&
- (iocb->ki_flags & IOCB_NOWAIT))
+ if (zonefs_zone_is_seq(zi) && !sync && (iocb->ki_flags & IOCB_NOWAIT))
return -EOPNOTSUPP;
if (iocb->ki_flags & IOCB_NOWAIT) {
@@ -554,7 +550,7 @@ static ssize_t zonefs_file_dio_write(struct kiocb *iocb, struct iov_iter *from)
}
/* Enforce sequential writes (append only) in sequential zones */
- if (zi->i_ztype == ZONEFS_ZTYPE_SEQ) {
+ if (zonefs_zone_is_seq(zi)) {
mutex_lock(&zi->i_truncate_mutex);
if (iocb->ki_pos != zi->i_wpoffset) {
mutex_unlock(&zi->i_truncate_mutex);
@@ -570,7 +566,7 @@ static ssize_t zonefs_file_dio_write(struct kiocb *iocb, struct iov_iter *from)
else
ret = iomap_dio_rw(iocb, from, &zonefs_write_iomap_ops,
&zonefs_write_dio_ops, 0, NULL, 0);
- if (zi->i_ztype == ZONEFS_ZTYPE_SEQ &&
+ if (zonefs_zone_is_seq(zi) &&
(ret > 0 || ret == -EIOCBQUEUED)) {
if (ret > 0)
count = ret;
@@ -596,14 +592,13 @@ static ssize_t zonefs_file_buffered_write(struct kiocb *iocb,
struct iov_iter *from)
{
struct inode *inode = file_inode(iocb->ki_filp);
- struct zonefs_inode_info *zi = ZONEFS_I(inode);
ssize_t ret;
/*
* Direct IO writes are mandatory for sequential zone files so that the
* write IO issuing order is preserved.
*/
- if (zi->i_ztype != ZONEFS_ZTYPE_CNV)
+ if (zonefs_inode_is_seq(inode))
return -EIO;
if (iocb->ki_flags & IOCB_NOWAIT) {
@@ -731,9 +726,7 @@ inode_unlock:
static inline bool zonefs_seq_file_need_wro(struct inode *inode,
struct file *file)
{
- struct zonefs_inode_info *zi = ZONEFS_I(inode);
-
- if (zi->i_ztype != ZONEFS_ZTYPE_SEQ)
+ if (zonefs_inode_is_cnv(inode))
return false;
if (!(file->f_mode & FMODE_WRITE))
diff --git a/fs/zonefs/super.c b/fs/zonefs/super.c
index 6307cc95be06..a4af29dc32e7 100644
--- a/fs/zonefs/super.c
+++ b/fs/zonefs/super.c
@@ -37,7 +37,7 @@ void zonefs_account_active(struct inode *inode)
lockdep_assert_held(&zi->i_truncate_mutex);
- if (zi->i_ztype != ZONEFS_ZTYPE_SEQ)
+ if (zonefs_zone_is_cnv(zi))
return;
/*
@@ -177,14 +177,14 @@ static loff_t zonefs_check_zone_condition(struct inode *inode,
zonefs_warn(inode->i_sb, "inode %lu: read-only zone\n",
inode->i_ino);
zi->i_flags |= ZONEFS_ZONE_READONLY;
- if (zi->i_ztype == ZONEFS_ZTYPE_CNV)
+ if (zonefs_zone_is_cnv(zi))
return zi->i_max_size;
return zi->i_wpoffset;
case BLK_ZONE_COND_FULL:
/* The write pointer of full zones is invalid. */
return zi->i_max_size;
default:
- if (zi->i_ztype == ZONEFS_ZTYPE_CNV)
+ if (zonefs_zone_is_cnv(zi))
return zi->i_max_size;
return (zone->wp - zone->start) << SECTOR_SHIFT;
}
@@ -260,7 +260,7 @@ static int zonefs_io_error_cb(struct blk_zone *zone, unsigned int idx,
* In all cases, warn about inode size inconsistency and handle the
* IO error according to the zone condition and to the mount options.
*/
- if (zi->i_ztype == ZONEFS_ZTYPE_SEQ && isize != data_size)
+ if (zonefs_zone_is_seq(zi) && isize != data_size)
zonefs_warn(sb, "inode %lu: invalid size %lld (should be %lld)\n",
inode->i_ino, isize, data_size);
@@ -584,7 +584,9 @@ static int zonefs_init_file_inode(struct inode *inode, struct blk_zone *zone,
inode->i_ino = zone->start >> sbi->s_zone_sectors_shift;
inode->i_mode = S_IFREG | sbi->s_perm;
- zi->i_ztype = type;
+ if (type == ZONEFS_ZTYPE_CNV)
+ zi->i_flags |= ZONEFS_ZONE_CNV;
+
zi->i_zsector = zone->start;
zi->i_zone_size = zone->len << SECTOR_SHIFT;
if (zi->i_zone_size > bdev_zone_sectors(sb->s_bdev) << SECTOR_SHIFT &&
diff --git a/fs/zonefs/zonefs.h b/fs/zonefs/zonefs.h
index 439096445ee5..1a225f74015a 100644
--- a/fs/zonefs/zonefs.h
+++ b/fs/zonefs/zonefs.h
@@ -44,6 +44,7 @@ static inline enum zonefs_ztype zonefs_zone_type(struct blk_zone *zone)
#define ZONEFS_ZONE_ACTIVE (1U << 2)
#define ZONEFS_ZONE_OFFLINE (1U << 3)
#define ZONEFS_ZONE_READONLY (1U << 4)
+#define ZONEFS_ZONE_CNV (1U << 31)
/*
* In-memory inode data.
@@ -51,9 +52,6 @@ static inline enum zonefs_ztype zonefs_zone_type(struct blk_zone *zone)
struct zonefs_inode_info {
struct inode i_vnode;
- /* File zone type */
- enum zonefs_ztype i_ztype;
-
/* File zone start sector (512B unit) */
sector_t i_zsector;
@@ -91,6 +89,26 @@ static inline struct zonefs_inode_info *ZONEFS_I(struct inode *inode)
return container_of(inode, struct zonefs_inode_info, i_vnode);
}
+static inline bool zonefs_zone_is_cnv(struct zonefs_inode_info *zi)
+{
+ return zi->i_flags & ZONEFS_ZONE_CNV;
+}
+
+static inline bool zonefs_zone_is_seq(struct zonefs_inode_info *zi)
+{
+ return !zonefs_zone_is_cnv(zi);
+}
+
+static inline bool zonefs_inode_is_cnv(struct inode *inode)
+{
+ return zonefs_zone_is_cnv(ZONEFS_I(inode));
+}
+
+static inline bool zonefs_inode_is_seq(struct inode *inode)
+{
+ return zonefs_zone_is_seq(ZONEFS_I(inode));
+}
+
/*
* On-disk super block (block 0).
*/