diff options
author | Johannes Thumshirn <johannes.thumshirn@wdc.com> | 2020-07-21 21:10:26 +0900 |
---|---|---|
committer | Damien Le Moal <damien.lemoal@wdc.com> | 2020-08-11 17:42:24 +0900 |
commit | e3c3155bc95ab6a7b21ac40418bf80bedb204949 (patch) | |
tree | 6ff49ead35604c82a93c6f70210d3990f357da5d /fs/zonefs | |
parent | 00e4db51259a5f936fec1424b884f029479d3981 (diff) | |
download | lwn-e3c3155bc95ab6a7b21ac40418bf80bedb204949.tar.gz lwn-e3c3155bc95ab6a7b21ac40418bf80bedb204949.zip |
zonefs: add zone-capacity support
In the zoned storage model, the sectors within a zone are typically all
writeable. With the introduction of the Zoned Namespace (ZNS) Command
Set in the NVM Express organization, the model was extended to have a
specific writeable capacity.
This zone capacity can be less than the overall zone size for a NVMe ZNS
device or null_blk in zoned-mode. For other ZBC/ZAC devices the zone
capacity is always equal to the zone size.
Use the zone capacity field instead from blk_zone for determining the
maximum inode size and inode blocks in zonefs.
Signed-off-by: Johannes Thumshirn <johannes.thumshirn@wdc.com>
Reviewed-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: Damien Le Moal <damien.lemoal@wdc.com>
Diffstat (limited to 'fs/zonefs')
-rw-r--r-- | fs/zonefs/super.c | 16 | ||||
-rw-r--r-- | fs/zonefs/zonefs.h | 3 |
2 files changed, 15 insertions, 4 deletions
diff --git a/fs/zonefs/super.c b/fs/zonefs/super.c index 4a0bff65d3d6..8ec7c8f109d7 100644 --- a/fs/zonefs/super.c +++ b/fs/zonefs/super.c @@ -335,7 +335,7 @@ static void zonefs_io_error(struct inode *inode, bool write) struct zonefs_sb_info *sbi = ZONEFS_SB(sb); unsigned int noio_flag; unsigned int nr_zones = - zi->i_max_size >> (sbi->s_zone_sectors_shift + SECTOR_SHIFT); + zi->i_zone_size >> (sbi->s_zone_sectors_shift + SECTOR_SHIFT); struct zonefs_ioerr_data err = { .inode = inode, .write = write, @@ -398,7 +398,7 @@ static int zonefs_file_truncate(struct inode *inode, loff_t isize) goto unlock; ret = blkdev_zone_mgmt(inode->i_sb->s_bdev, op, zi->i_zsector, - zi->i_max_size >> SECTOR_SHIFT, GFP_NOFS); + zi->i_zone_size >> SECTOR_SHIFT, GFP_NOFS); if (ret) { zonefs_err(inode->i_sb, "Zone management operation at %llu failed %d", @@ -1053,14 +1053,16 @@ static void zonefs_init_file_inode(struct inode *inode, struct blk_zone *zone, zi->i_ztype = type; zi->i_zsector = zone->start; + zi->i_zone_size = zone->len << SECTOR_SHIFT; + zi->i_max_size = min_t(loff_t, MAX_LFS_FILESIZE, - zone->len << SECTOR_SHIFT); + zone->capacity << SECTOR_SHIFT); zi->i_wpoffset = zonefs_check_zone_condition(inode, zone, true, true); inode->i_uid = sbi->s_uid; inode->i_gid = sbi->s_gid; inode->i_size = zi->i_wpoffset; - inode->i_blocks = zone->len; + inode->i_blocks = zi->i_max_size >> SECTOR_SHIFT; inode->i_op = &zonefs_file_inode_operations; inode->i_fop = &zonefs_file_operations; @@ -1167,12 +1169,18 @@ static int zonefs_create_zgroup(struct zonefs_zone_data *zd, if (zonefs_zone_type(next) != type) break; zone->len += next->len; + zone->capacity += next->capacity; if (next->cond == BLK_ZONE_COND_READONLY && zone->cond != BLK_ZONE_COND_OFFLINE) zone->cond = BLK_ZONE_COND_READONLY; else if (next->cond == BLK_ZONE_COND_OFFLINE) zone->cond = BLK_ZONE_COND_OFFLINE; } + if (zone->capacity != zone->len) { + zonefs_err(sb, "Invalid conventional zone capacity\n"); + ret = -EINVAL; + goto free; + } } /* diff --git a/fs/zonefs/zonefs.h b/fs/zonefs/zonefs.h index ad17fef7ce91..55b39970acb2 100644 --- a/fs/zonefs/zonefs.h +++ b/fs/zonefs/zonefs.h @@ -56,6 +56,9 @@ struct zonefs_inode_info { /* File maximum size */ loff_t i_max_size; + /* File zone size */ + loff_t i_zone_size; + /* * To serialise fully against both syscall and mmap based IO and * sequential file truncation, two locks are used. For serializing |