summaryrefslogtreecommitdiff
path: root/drivers/md
diff options
context:
space:
mode:
authorYu Kuai <yukuai3@huawei.com>2024-06-15 16:51:43 +0800
committerSong Liu <song@kernel.org>2024-07-04 06:11:53 +0000
commit2314c2e3a70521f055dd011245dccf6fd97c7ee0 (patch)
treedc68a2e350ab0df67788a6cf973768b2cc7476b4 /drivers/md
parent98d34c087249d39838874b83e17671e7d5eb1ca7 (diff)
downloadlwn-2314c2e3a70521f055dd011245dccf6fd97c7ee0.tar.gz
lwn-2314c2e3a70521f055dd011245dccf6fd97c7ee0.zip
md/raid5: fix spares errors about rcu usage
As commit ad8606702f26 ("md/raid5: remove rcu protection to access rdev from conf") explains, rcu protection can be removed, however, there are three places left, there won't be any real problems. drivers/md/raid5.c:8071:24: error: incompatible types in comparison expression (different address spaces): drivers/md/raid5.c:8071:24: struct md_rdev [noderef] __rcu * drivers/md/raid5.c:8071:24: struct md_rdev * drivers/md/raid5.c:7569:25: error: incompatible types in comparison expression (different address spaces): drivers/md/raid5.c:7569:25: struct md_rdev [noderef] __rcu * drivers/md/raid5.c:7569:25: struct md_rdev * drivers/md/raid5.c:7573:25: error: incompatible types in comparison expression (different address spaces): drivers/md/raid5.c:7573:25: struct md_rdev [noderef] __rcu * drivers/md/raid5.c:7573:25: struct md_rdev * Fixes: ad8606702f26 ("md/raid5: remove rcu protection to access rdev from conf") Cc: stable@vger.kernel.org Signed-off-by: Yu Kuai <yukuai3@huawei.com> Signed-off-by: Song Liu <song@kernel.org> Link: https://lore.kernel.org/r/20240615085143.1648223-1-yukuai1@huaweicloud.com
Diffstat (limited to 'drivers/md')
-rw-r--r--drivers/md/raid5.c12
1 files changed, 5 insertions, 7 deletions
diff --git a/drivers/md/raid5.c b/drivers/md/raid5.c
index 10219205160b..825fa629db33 100644
--- a/drivers/md/raid5.c
+++ b/drivers/md/raid5.c
@@ -155,7 +155,7 @@ static int raid6_idx_to_slot(int idx, struct stripe_head *sh,
return slot;
}
-static void print_raid5_conf (struct r5conf *conf);
+static void print_raid5_conf(struct r5conf *conf);
static int stripe_operations_active(struct stripe_head *sh)
{
@@ -7568,11 +7568,11 @@ static struct r5conf *setup_conf(struct mddev *mddev)
if (test_bit(Replacement, &rdev->flags)) {
if (disk->replacement)
goto abort;
- RCU_INIT_POINTER(disk->replacement, rdev);
+ disk->replacement = rdev;
} else {
if (disk->rdev)
goto abort;
- RCU_INIT_POINTER(disk->rdev, rdev);
+ disk->rdev = rdev;
}
if (test_bit(In_sync, &rdev->flags)) {
@@ -8054,7 +8054,7 @@ static void raid5_status(struct seq_file *seq, struct mddev *mddev)
seq_printf (seq, "]");
}
-static void print_raid5_conf (struct r5conf *conf)
+static void print_raid5_conf(struct r5conf *conf)
{
struct md_rdev *rdev;
int i;
@@ -8068,15 +8068,13 @@ static void print_raid5_conf (struct r5conf *conf)
conf->raid_disks,
conf->raid_disks - conf->mddev->degraded);
- rcu_read_lock();
for (i = 0; i < conf->raid_disks; i++) {
- rdev = rcu_dereference(conf->disks[i].rdev);
+ rdev = conf->disks[i].rdev;
if (rdev)
pr_debug(" disk %d, o:%d, dev:%pg\n",
i, !test_bit(Faulty, &rdev->flags),
rdev->bdev);
}
- rcu_read_unlock();
}
static int raid5_spare_active(struct mddev *mddev)