summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorNeil Horman <nhorman@tuxdriver.com>2012-05-01 08:18:02 +0000
committerBen Hutchings <ben@decadent.org.uk>2012-08-10 00:25:16 +0100
commit1b51d69a5437f82c7345765d602771cb8452f2f6 (patch)
tree96cbaf5c47d3e4334c7d5b64b610d1410ccd7e28
parentea39e338f9bb5eb5b3e568cbe7475549d67ef128 (diff)
downloadlwn-1b51d69a5437f82c7345765d602771cb8452f2f6.tar.gz
lwn-1b51d69a5437f82c7345765d602771cb8452f2f6.zip
drop_monitor: prevent init path from scheduling on the wrong cpu
commit 4fdcfa12843bca38d0c9deff70c8720e4e8f515f upstream. I just noticed after some recent updates, that the init path for the drop monitor protocol has a minor error. drop monitor maintains a per cpu structure, that gets initalized from a single cpu. Normally this is fine, as the protocol isn't in use yet, but I recently made a change that causes a failed skb allocation to reschedule itself . Given the current code, the implication is that this workqueue reschedule will take place on the wrong cpu. If drop monitor is used early during the boot process, its possible that two cpus will access a single per-cpu structure in parallel, possibly leading to data corruption. This patch fixes the situation, by storing the cpu number that a given instance of this per-cpu data should be accessed from. In the case of a need for a reschedule, the cpu stored in the struct is assigned the rescheule, rather than the currently executing cpu Tested successfully by myself. Signed-off-by: Neil Horman <nhorman@tuxdriver.com> CC: David Miller <davem@davemloft.net> Signed-off-by: David S. Miller <davem@davemloft.net> Signed-off-by: Ben Hutchings <ben@decadent.org.uk>
-rw-r--r--net/core/drop_monitor.c12
1 files changed, 7 insertions, 5 deletions
diff --git a/net/core/drop_monitor.c b/net/core/drop_monitor.c
index d75cbfc30d03..e8365921e07f 100644
--- a/net/core/drop_monitor.c
+++ b/net/core/drop_monitor.c
@@ -49,6 +49,7 @@ struct per_cpu_dm_data {
struct sk_buff __rcu *skb;
atomic_t dm_hit_count;
struct timer_list send_timer;
+ int cpu;
};
struct dm_hw_stat_delta {
@@ -73,7 +74,6 @@ static int dm_hit_limit = 64;
static int dm_delay = 1;
static unsigned long dm_hw_check_delta = 2*HZ;
static LIST_HEAD(hw_stats_list);
-static int initialized = 0;
static void reset_per_cpu_data(struct per_cpu_dm_data *data)
{
@@ -96,8 +96,8 @@ static void reset_per_cpu_data(struct per_cpu_dm_data *data)
sizeof(struct net_dm_alert_msg));
msg = nla_data(nla);
memset(msg, 0, al);
- } else if (initialized)
- schedule_work_on(smp_processor_id(), &data->dm_alert_work);
+ } else
+ schedule_work_on(data->cpu, &data->dm_alert_work);
/*
* Don't need to lock this, since we are guaranteed to only
@@ -121,6 +121,8 @@ static void send_dm_alert(struct work_struct *unused)
struct sk_buff *skb;
struct per_cpu_dm_data *data = &get_cpu_var(dm_cpu_data);
+ WARN_ON_ONCE(data->cpu != smp_processor_id());
+
/*
* Grab the skb we're about to send
*/
@@ -403,14 +405,14 @@ static int __init init_net_drop_monitor(void)
for_each_present_cpu(cpu) {
data = &per_cpu(dm_cpu_data, cpu);
- reset_per_cpu_data(data);
+ data->cpu = cpu;
INIT_WORK(&data->dm_alert_work, send_dm_alert);
init_timer(&data->send_timer);
data->send_timer.data = cpu;
data->send_timer.function = sched_send_work;
+ reset_per_cpu_data(data);
}
- initialized = 1;
goto out;