summaryrefslogblamecommitdiff
path: root/drivers/macintosh/windfarm_pm121.c
blob: af605e915d4196422681b6cd809d8aee3eadf600 (plain) (tree)
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
























































































































































































































                                                                           









































































































































































































































































                                                                             
                                              
























































































































































































































































































































































































































































































































                                                                                    
                                                     






                                              
                               










                                          
                                                     




























                                                                 
/*
 * Windfarm PowerMac thermal control. iMac G5 iSight
 *
 * (c) Copyright 2007 Étienne Bersac <bersace@gmail.com>
 *
 * Bits & pieces from windfarm_pm81.c by (c) Copyright 2005 Benjamin
 * Herrenschmidt, IBM Corp. <benh@kernel.crashing.org>
 *
 * Released under the term of the GNU GPL v2.
 *
 *
 *
 * PowerMac12,1
 * ============
 *
 *
 * The algorithm used is the PID control algorithm, used the same way
 * the published Darwin code does, using the same values that are
 * present in the Darwin 8.10 snapshot property lists (note however
 * that none of the code has been re-used, it's a complete
 * re-implementation
 *
 * There is two models using PowerMac12,1. Model 2 is iMac G5 iSight
 * 17" while Model 3 is iMac G5 20". They do have both the same
 * controls with a tiny difference. The control-ids of hard-drive-fan
 * and cpu-fan is swapped.
 *
 *
 * Target Correction :
 *
 * controls have a target correction calculated as :
 *
 * new_min = ((((average_power * slope) >> 16) + offset) >> 16) + min_value
 * new_value = max(new_value, max(new_min, 0))
 *
 * OD Fan control correction.
 *
 * # model_id: 2
 *   offset		: -19563152
 *   slope		:  1956315
 *
 * # model_id: 3
 *   offset		: -15650652
 *   slope		:  1565065
 *
 * HD Fan control correction.
 *
 * # model_id: 2
 *   offset		: -15650652
 *   slope		:  1565065
 *
 * # model_id: 3
 *   offset		: -19563152
 *   slope		:  1956315
 *
 * CPU Fan control correction.
 *
 * # model_id: 2
 *   offset		: -25431900
 *   slope		:  2543190
 *
 * # model_id: 3
 *   offset		: -15650652
 *   slope		:  1565065
 *
 *
 * Target rubber-banding :
 *
 * Some controls have a target correction which depends on another
 * control value. The correction is computed in the following way :
 *
 * new_min = ref_value * slope + offset
 *
 * ref_value is the value of the reference control. If new_min is
 * greater than 0, then we correct the target value using :
 *
 * new_target = max (new_target, new_min >> 16)
 *
 *
 * # model_id : 2
 *   control	: cpu-fan
 *   ref	: optical-drive-fan
 *   offset	: -15650652
 *   slope	: 1565065
 *
 * # model_id : 3
 *   control	: optical-drive-fan
 *   ref	: hard-drive-fan
 *   offset	: -32768000
 *   slope	: 65536
 *
 *
 * In order to have the moste efficient correction with those
 * dependencies, we must trigger HD loop before OD loop before CPU
 * loop.
 *
 *
 * The various control loops found in Darwin config file are:
 *
 * HD Fan control loop.
 *
 * # model_id: 2
 *   control        : hard-drive-fan
 *   sensor         : hard-drive-temp
 *   PID params     : G_d = 0x00000000
 *                    G_p = 0x002D70A3
 *                    G_r = 0x00019999
 *                    History = 2 entries
 *                    Input target = 0x370000
 *                    Interval = 5s
 *
 * # model_id: 3
 *   control        : hard-drive-fan
 *   sensor         : hard-drive-temp
 *   PID params     : G_d = 0x00000000
 *                    G_p = 0x002170A3
 *                    G_r = 0x00019999
 *                    History = 2 entries
 *                    Input target = 0x370000
 *                    Interval = 5s
 *
 * OD Fan control loop.
 *
 * # model_id: 2
 *   control        : optical-drive-fan
 *   sensor         : optical-drive-temp
 *   PID params     : G_d = 0x00000000
 *                    G_p = 0x001FAE14
 *                    G_r = 0x00019999
 *                    History = 2 entries
 *                    Input target = 0x320000
 *                    Interval = 5s
 *
 * # model_id: 3
 *   control        : optical-drive-fan
 *   sensor         : optical-drive-temp
 *   PID params     : G_d = 0x00000000
 *                    G_p = 0x001FAE14
 *                    G_r = 0x00019999
 *                    History = 2 entries
 *                    Input target = 0x320000
 *                    Interval = 5s
 *
 * GPU Fan control loop.
 *
 * # model_id: 2
 *   control        : hard-drive-fan
 *   sensor         : gpu-temp
 *   PID params     : G_d = 0x00000000
 *                    G_p = 0x002A6666
 *                    G_r = 0x00019999
 *                    History = 2 entries
 *                    Input target = 0x5A0000
 *                    Interval = 5s
 *
 * # model_id: 3
 *   control        : cpu-fan
 *   sensor         : gpu-temp
 *   PID params     : G_d = 0x00000000
 *                    G_p = 0x0010CCCC
 *                    G_r = 0x00019999
 *                    History = 2 entries
 *                    Input target = 0x500000
 *                    Interval = 5s
 *
 * KODIAK (aka northbridge) Fan control loop.
 *
 * # model_id: 2
 *   control        : optical-drive-fan
 *   sensor         : north-bridge-temp
 *   PID params     : G_d = 0x00000000
 *                    G_p = 0x003BD70A
 *                    G_r = 0x00019999
 *                    History = 2 entries
 *                    Input target = 0x550000
 *                    Interval = 5s
 *
 * # model_id: 3
 *   control        : hard-drive-fan
 *   sensor         : north-bridge-temp
 *   PID params     : G_d = 0x00000000
 *                    G_p = 0x0030F5C2
 *                    G_r = 0x00019999
 *                    History = 2 entries
 *                    Input target = 0x550000
 *                    Interval = 5s
 *
 * CPU Fan control loop.
 *
 *   control        : cpu-fan
 *   sensors        : cpu-temp, cpu-power
 *   PID params     : from SDB partition
 *
 *
 * CPU Slew control loop.
 *
 *   control        : cpufreq-clamp
 *   sensor         : cpu-temp
 *
 */

#undef	DEBUG

#include <linux/types.h>
#include <linux/errno.h>
#include <linux/kernel.h>
#include <linux/delay.h>
#include <linux/slab.h>
#include <linux/init.h>
#include <linux/spinlock.h>
#include <linux/wait.h>
#include <linux/kmod.h>
#include <linux/device.h>
#include <linux/platform_device.h>
#include <asm/prom.h>
#include <asm/machdep.h>
#include <asm/io.h>
#include <asm/sections.h>
#include <asm/smu.h>

#include "windfarm.h"
#include "windfarm_pid.h"

#define VERSION "0.3"

static int pm121_mach_model;	/* machine model id */

/* Controls & sensors */
static struct wf_sensor	*sensor_cpu_power;
static struct wf_sensor	*sensor_cpu_temp;
static struct wf_sensor	*sensor_cpu_voltage;
static struct wf_sensor	*sensor_cpu_current;
static struct wf_sensor	*sensor_gpu_temp;
static struct wf_sensor	*sensor_north_bridge_temp;
static struct wf_sensor	*sensor_hard_drive_temp;
static struct wf_sensor	*sensor_optical_drive_temp;
static struct wf_sensor	*sensor_incoming_air_temp; /* unused ! */

enum {
	FAN_CPU,
	FAN_HD,
	FAN_OD,
	CPUFREQ,
	N_CONTROLS
};
static struct wf_control *controls[N_CONTROLS] = {};

/* Set to kick the control loop into life */
static int pm121_all_controls_ok, pm121_all_sensors_ok, pm121_started;

enum {
	FAILURE_FAN		= 1 << 0,
	FAILURE_SENSOR		= 1 << 1,
	FAILURE_OVERTEMP	= 1 << 2
};

/* All sys loops. Note the HD before the OD loop in order to have it
   run before. */
enum {
	LOOP_GPU,		/* control = hd or cpu, but luckily,
				   it doesn't matter */
	LOOP_HD,		/* control = hd */
	LOOP_KODIAK,		/* control = hd or od */
	LOOP_OD,		/* control = od */
	N_LOOPS
};

static const char *loop_names[N_LOOPS] = {
	"GPU",
	"HD",
	"KODIAK",
	"OD",
};

#define	PM121_NUM_CONFIGS	2

static unsigned int pm121_failure_state;
static int pm121_readjust, pm121_skipping;
static s32 average_power;

struct pm121_correction {
	int	offset;
	int	slope;
};

static struct pm121_correction corrections[N_CONTROLS][PM121_NUM_CONFIGS] = {
	/* FAN_OD */
	{
		/* MODEL 2 */
		{ .offset	= -19563152,
		  .slope	=  1956315
		},
		/* MODEL 3 */
		{ .offset	= -15650652,
		  .slope	=  1565065
		},
	},
	/* FAN_HD */
	{
		/* MODEL 2 */
		{ .offset	= -15650652,
		  .slope	=  1565065
		},
		/* MODEL 3 */
		{ .offset	= -19563152,
		  .slope	=  1956315
		},
	},
	/* FAN_CPU */
	{
		/* MODEL 2 */
		{ .offset	= -25431900,
		  .slope	=  2543190
		},
		/* MODEL 3 */
		{ .offset	= -15650652,
		  .slope	=  1565065
		},
	},
	/* CPUFREQ has no correction (and is not implemented at all) */
};

struct pm121_connection {
	unsigned int	control_id;
	unsigned int	ref_id;
	struct pm121_correction	correction;
};

static struct pm121_connection pm121_connections[] = {
	/* MODEL 2 */
	{ .control_id	= FAN_CPU,
	  .ref_id	= FAN_OD,
	  { .offset	= -32768000,
	    .slope	=  65536
	  }
	},
	/* MODEL 3 */
	{ .control_id	= FAN_OD,
	  .ref_id	= FAN_HD,
	  { .offset	= -32768000,
	    .slope	=  65536
	  }
	},
};

/* pointer to the current model connection */
static struct pm121_connection *pm121_connection;

/*
 * ****** System Fans Control Loop ******
 *
 */

/* Since each loop handles only one control and we want to avoid
 * writing virtual control, we store the control correction with the
 * loop params. Some data are not set, there are common to all loop
 * and thus, hardcoded.
 */
struct pm121_sys_param {
	/* purely informative since we use mach_model-2 as index */
	int			model_id;
	struct wf_sensor	**sensor; /* use sensor_id instead ? */
	s32			gp, itarget;
	unsigned int		control_id;
};

static struct pm121_sys_param
pm121_sys_all_params[N_LOOPS][PM121_NUM_CONFIGS] = {
	/* GPU Fan control loop */
	{
		{ .model_id	= 2,
		  .sensor	= &sensor_gpu_temp,
		  .gp		= 0x002A6666,
		  .itarget	= 0x5A0000,
		  .control_id	= FAN_HD,
		},
		{ .model_id	= 3,
		  .sensor	= &sensor_gpu_temp,
		  .gp		= 0x0010CCCC,
		  .itarget	= 0x500000,
		  .control_id	= FAN_CPU,
		},
	},
	/* HD Fan control loop */
	{
		{ .model_id	= 2,
		  .sensor	= &sensor_hard_drive_temp,
		  .gp		= 0x002D70A3,
		  .itarget	= 0x370000,
		  .control_id	= FAN_HD,
		},
		{ .model_id	= 3,
		  .sensor	= &sensor_hard_drive_temp,
		  .gp		= 0x002170A3,
		  .itarget	= 0x370000,
		  .control_id	= FAN_HD,
		},
	},
	/* KODIAK Fan control loop */
	{
		{ .model_id	= 2,
		  .sensor	= &sensor_north_bridge_temp,
		  .gp		= 0x003BD70A,
		  .itarget	= 0x550000,
		  .control_id	= FAN_OD,
		},
		{ .model_id	= 3,
		  .sensor	= &sensor_north_bridge_temp,
		  .gp		= 0x0030F5C2,
		  .itarget	= 0x550000,
		  .control_id	= FAN_HD,
		},
	},
	/* OD Fan control loop */
	{
		{ .model_id	= 2,
		  .sensor	= &sensor_optical_drive_temp,
		  .gp		= 0x001FAE14,
		  .itarget	= 0x320000,
		  .control_id	= FAN_OD,
		},
		{ .model_id	= 3,
		  .sensor	= &sensor_optical_drive_temp,
		  .gp		= 0x001FAE14,
		  .itarget	= 0x320000,
		  .control_id	= FAN_OD,
		},
	},
};

/* the hardcoded values */
#define	PM121_SYS_GD		0x00000000
#define	PM121_SYS_GR		0x00019999
#define	PM121_SYS_HISTORY_SIZE	2
#define	PM121_SYS_INTERVAL	5

/* State data used by the system fans control loop
 */
struct pm121_sys_state {
	int			ticks;
	s32			setpoint;
	struct wf_pid_state	pid;
};

struct pm121_sys_state *pm121_sys_state[N_LOOPS] = {};

/*
 * ****** CPU Fans Control Loop ******
 *
 */

#define PM121_CPU_INTERVAL	1

/* State data used by the cpu fans control loop
 */
struct pm121_cpu_state {
	int			ticks;
	s32			setpoint;
	struct wf_cpu_pid_state	pid;
};

static struct pm121_cpu_state *pm121_cpu_state;



/*
 * ***** Implementation *****
 *
 */

/* correction the value using the output-low-bound correction algo */
static s32 pm121_correct(s32 new_setpoint,
			 unsigned int control_id,
			 s32 min)
{
	s32 new_min;
	struct pm121_correction *correction;
	correction = &corrections[control_id][pm121_mach_model - 2];

	new_min = (average_power * correction->slope) >> 16;
	new_min += correction->offset;
	new_min = (new_min >> 16) + min;

	return max3(new_setpoint, new_min, 0);
}

static s32 pm121_connect(unsigned int control_id, s32 setpoint)
{
	s32 new_min, value, new_setpoint;

	if (pm121_connection->control_id == control_id) {
		controls[control_id]->ops->get_value(controls[control_id],
						     &value);
		new_min = value * pm121_connection->correction.slope;
		new_min += pm121_connection->correction.offset;
		if (new_min > 0) {
			new_setpoint = max(setpoint, (new_min >> 16));
			if (new_setpoint != setpoint) {
				pr_debug("pm121: %s depending on %s, "
					 "corrected from %d to %d RPM\n",
					 controls[control_id]->name,
					 controls[pm121_connection->ref_id]->name,
					 (int) setpoint, (int) new_setpoint);
			}
		} else
			new_setpoint = setpoint;
	}
	/* no connection */
	else
		new_setpoint = setpoint;

	return new_setpoint;
}

/* FAN LOOPS */
static void pm121_create_sys_fans(int loop_id)
{
	struct pm121_sys_param *param = NULL;
	struct wf_pid_param pid_param;
	struct wf_control *control = NULL;
	int i;

	/* First, locate the params for this model */
	for (i = 0; i < PM121_NUM_CONFIGS; i++) {
		if (pm121_sys_all_params[loop_id][i].model_id == pm121_mach_model) {
			param = &(pm121_sys_all_params[loop_id][i]);
			break;
		}
	}

	/* No params found, put fans to max */
	if (param == NULL) {
		printk(KERN_WARNING "pm121: %s fan config not found "
		       " for this machine model\n",
		       loop_names[loop_id]);
		goto fail;
	}

	control = controls[param->control_id];

	/* Alloc & initialize state */
	pm121_sys_state[loop_id] = kmalloc(sizeof(struct pm121_sys_state),
					   GFP_KERNEL);
	if (pm121_sys_state[loop_id] == NULL) {
		printk(KERN_WARNING "pm121: Memory allocation error\n");
		goto fail;
	}
	pm121_sys_state[loop_id]->ticks = 1;

	/* Fill PID params */
	pid_param.gd		= PM121_SYS_GD;
	pid_param.gp		= param->gp;
	pid_param.gr		= PM121_SYS_GR;
	pid_param.interval	= PM121_SYS_INTERVAL;
	pid_param.history_len	= PM121_SYS_HISTORY_SIZE;
	pid_param.itarget	= param->itarget;
	pid_param.min		= control->ops->get_min(control);
	pid_param.max		= control->ops->get_max(control);

	wf_pid_init(&pm121_sys_state[loop_id]->pid, &pid_param);

	pr_debug("pm121: %s Fan control loop initialized.\n"
		 "       itarged=%d.%03d, min=%d RPM, max=%d RPM\n",
		 loop_names[loop_id], FIX32TOPRINT(pid_param.itarget),
		 pid_param.min, pid_param.max);
	return;

 fail:
	/* note that this is not optimal since another loop may still
	   control the same control */
	printk(KERN_WARNING "pm121: failed to set up %s loop "
	       "setting \"%s\" to max speed.\n",
	       loop_names[loop_id], control->name);

	if (control)
		wf_control_set_max(control);
}

static void pm121_sys_fans_tick(int loop_id)
{
	struct pm121_sys_param *param;
	struct pm121_sys_state *st;
	struct wf_sensor *sensor;
	struct wf_control *control;
	s32 temp, new_setpoint;
	int rc;

	param = &(pm121_sys_all_params[loop_id][pm121_mach_model-2]);
	st = pm121_sys_state[loop_id];
	sensor = *(param->sensor);
	control = controls[param->control_id];

	if (--st->ticks != 0) {
		if (pm121_readjust)
			goto readjust;
		return;
	}
	st->ticks = PM121_SYS_INTERVAL;

	rc = sensor->ops->get_value(sensor, &temp);
	if (rc) {
		printk(KERN_WARNING "windfarm: %s sensor error %d\n",
		       sensor->name, rc);
		pm121_failure_state |= FAILURE_SENSOR;
		return;
	}

	pr_debug("pm121: %s Fan tick ! %s: %d.%03d\n",
		 loop_names[loop_id], sensor->name,
		 FIX32TOPRINT(temp));

	new_setpoint = wf_pid_run(&st->pid, temp);

	/* correction */
	new_setpoint = pm121_correct(new_setpoint,
				     param->control_id,
				     st->pid.param.min);
	/* linked corretion */
	new_setpoint = pm121_connect(param->control_id, new_setpoint);

	if (new_setpoint == st->setpoint)
		return;
	st->setpoint = new_setpoint;
	pr_debug("pm121: %s corrected setpoint: %d RPM\n",
		 control->name, (int)new_setpoint);
 readjust:
	if (control && pm121_failure_state == 0) {
		rc = control->ops->set_value(control, st->setpoint);
		if (rc) {
			printk(KERN_WARNING "windfarm: %s fan error %d\n",
			       control->name, rc);
			pm121_failure_state |= FAILURE_FAN;
		}
	}
}


/* CPU LOOP */
static void pm121_create_cpu_fans(void)
{
	struct wf_cpu_pid_param pid_param;
	const struct smu_sdbp_header *hdr;
	struct smu_sdbp_cpupiddata *piddata;
	struct smu_sdbp_fvt *fvt;
	struct wf_control *fan_cpu;
	s32 tmax, tdelta, maxpow, powadj;

	fan_cpu = controls[FAN_CPU];

	/* First, locate the PID params in SMU SBD */
	hdr = smu_get_sdb_partition(SMU_SDB_CPUPIDDATA_ID, NULL);
	if (hdr == 0) {
		printk(KERN_WARNING "pm121: CPU PID fan config not found.\n");
		goto fail;
	}
	piddata = (struct smu_sdbp_cpupiddata *)&hdr[1];

	/* Get the FVT params for operating point 0 (the only supported one
	 * for now) in order to get tmax
	 */
	hdr = smu_get_sdb_partition(SMU_SDB_FVT_ID, NULL);
	if (hdr) {
		fvt = (struct smu_sdbp_fvt *)&hdr[1];
		tmax = ((s32)fvt->maxtemp) << 16;
	} else
		tmax = 0x5e0000; /* 94 degree default */

	/* Alloc & initialize state */
	pm121_cpu_state = kmalloc(sizeof(struct pm121_cpu_state),
				  GFP_KERNEL);
	if (pm121_cpu_state == NULL)
		goto fail;
	pm121_cpu_state->ticks = 1;

	/* Fill PID params */
	pid_param.interval = PM121_CPU_INTERVAL;
	pid_param.history_len = piddata->history_len;
	if (pid_param.history_len > WF_CPU_PID_MAX_HISTORY) {
		printk(KERN_WARNING "pm121: History size overflow on "
		       "CPU control loop (%d)\n", piddata->history_len);
		pid_param.history_len = WF_CPU_PID_MAX_HISTORY;
	}
	pid_param.gd = piddata->gd;
	pid_param.gp = piddata->gp;
	pid_param.gr = piddata->gr / pid_param.history_len;

	tdelta = ((s32)piddata->target_temp_delta) << 16;
	maxpow = ((s32)piddata->max_power) << 16;
	powadj = ((s32)piddata->power_adj) << 16;

	pid_param.tmax = tmax;
	pid_param.ttarget = tmax - tdelta;
	pid_param.pmaxadj = maxpow - powadj;

	pid_param.min = fan_cpu->ops->get_min(fan_cpu);
	pid_param.max = fan_cpu->ops->get_max(fan_cpu);

	wf_cpu_pid_init(&pm121_cpu_state->pid, &pid_param);

	pr_debug("pm121: CPU Fan control initialized.\n");
	pr_debug("       ttarged=%d.%03d, tmax=%d.%03d, min=%d RPM, max=%d RPM,\n",
		 FIX32TOPRINT(pid_param.ttarget), FIX32TOPRINT(pid_param.tmax),
		 pid_param.min, pid_param.max);

	return;

 fail:
	printk(KERN_WARNING "pm121: CPU fan config not found, max fan speed\n");

	if (controls[CPUFREQ])
		wf_control_set_max(controls[CPUFREQ]);
	if (fan_cpu)
		wf_control_set_max(fan_cpu);
}


static void pm121_cpu_fans_tick(struct pm121_cpu_state *st)
{
	s32 new_setpoint, temp, power;
	struct wf_control *fan_cpu = NULL;
	int rc;

	if (--st->ticks != 0) {
		if (pm121_readjust)
			goto readjust;
		return;
	}
	st->ticks = PM121_CPU_INTERVAL;

	fan_cpu = controls[FAN_CPU];

	rc = sensor_cpu_temp->ops->get_value(sensor_cpu_temp, &temp);
	if (rc) {
		printk(KERN_WARNING "pm121: CPU temp sensor error %d\n",
		       rc);
		pm121_failure_state |= FAILURE_SENSOR;
		return;
	}

	rc = sensor_cpu_power->ops->get_value(sensor_cpu_power, &power);
	if (rc) {
		printk(KERN_WARNING "pm121: CPU power sensor error %d\n",
		       rc);
		pm121_failure_state |= FAILURE_SENSOR;
		return;
	}

	pr_debug("pm121: CPU Fans tick ! CPU temp: %d.%03d°C, power: %d.%03d\n",
		 FIX32TOPRINT(temp), FIX32TOPRINT(power));

	if (temp > st->pid.param.tmax)
		pm121_failure_state |= FAILURE_OVERTEMP;

	new_setpoint = wf_cpu_pid_run(&st->pid, power, temp);

	/* correction */
	new_setpoint = pm121_correct(new_setpoint,
				     FAN_CPU,
				     st->pid.param.min);

	/* connected correction */
	new_setpoint = pm121_connect(FAN_CPU, new_setpoint);

	if (st->setpoint == new_setpoint)
		return;
	st->setpoint = new_setpoint;
	pr_debug("pm121: CPU corrected setpoint: %d RPM\n", (int)new_setpoint);

 readjust:
	if (fan_cpu && pm121_failure_state == 0) {
		rc = fan_cpu->ops->set_value(fan_cpu, st->setpoint);
		if (rc) {
			printk(KERN_WARNING "pm121: %s fan error %d\n",
			       fan_cpu->name, rc);
			pm121_failure_state |= FAILURE_FAN;
		}
	}
}

/*
 * ****** Common ******
 *
 */

static void pm121_tick(void)
{
	unsigned int last_failure = pm121_failure_state;
	unsigned int new_failure;
	s32 total_power;
	int i;

	if (!pm121_started) {
		pr_debug("pm121: creating control loops !\n");
		for (i = 0; i < N_LOOPS; i++)
			pm121_create_sys_fans(i);

		pm121_create_cpu_fans();
		pm121_started = 1;
	}

	/* skipping ticks */
	if (pm121_skipping && --pm121_skipping)
		return;

	/* compute average power */
	total_power = 0;
	for (i = 0; i < pm121_cpu_state->pid.param.history_len; i++)
		total_power += pm121_cpu_state->pid.powers[i];

	average_power = total_power / pm121_cpu_state->pid.param.history_len;


	pm121_failure_state = 0;
	for (i = 0 ; i < N_LOOPS; i++) {
		if (pm121_sys_state[i])
			pm121_sys_fans_tick(i);
	}

	if (pm121_cpu_state)
		pm121_cpu_fans_tick(pm121_cpu_state);

	pm121_readjust = 0;
	new_failure = pm121_failure_state & ~last_failure;

	/* If entering failure mode, clamp cpufreq and ramp all
	 * fans to full speed.
	 */
	if (pm121_failure_state && !last_failure) {
		for (i = 0; i < N_CONTROLS; i++) {
			if (controls[i])
				wf_control_set_max(controls[i]);
		}
	}

	/* If leaving failure mode, unclamp cpufreq and readjust
	 * all fans on next iteration
	 */
	if (!pm121_failure_state && last_failure) {
		if (controls[CPUFREQ])
			wf_control_set_min(controls[CPUFREQ]);
		pm121_readjust = 1;
	}

	/* Overtemp condition detected, notify and start skipping a couple
	 * ticks to let the temperature go down
	 */
	if (new_failure & FAILURE_OVERTEMP) {
		wf_set_overtemp();
		pm121_skipping = 2;
	}

	/* We only clear the overtemp condition if overtemp is cleared
	 * _and_ no other failure is present. Since a sensor error will
	 * clear the overtemp condition (can't measure temperature) at
	 * the control loop levels, but we don't want to keep it clear
	 * here in this case
	 */
	if (new_failure == 0 && last_failure & FAILURE_OVERTEMP)
		wf_clear_overtemp();
}


static struct wf_control* pm121_register_control(struct wf_control *ct,
						 const char *match,
						 unsigned int id)
{
	if (controls[id] == NULL && !strcmp(ct->name, match)) {
		if (wf_get_control(ct) == 0)
			controls[id] = ct;
	}
	return controls[id];
}

static void pm121_new_control(struct wf_control *ct)
{
	int all = 1;

	if (pm121_all_controls_ok)
		return;

	all = pm121_register_control(ct, "optical-drive-fan", FAN_OD) && all;
	all = pm121_register_control(ct, "hard-drive-fan", FAN_HD) && all;
	all = pm121_register_control(ct, "cpu-fan", FAN_CPU) && all;
	all = pm121_register_control(ct, "cpufreq-clamp", CPUFREQ) && all;

	if (all)
		pm121_all_controls_ok = 1;
}




static struct wf_sensor* pm121_register_sensor(struct wf_sensor *sensor,
					       const char *match,
					       struct wf_sensor **var)
{
	if (*var == NULL && !strcmp(sensor->name, match)) {
		if (wf_get_sensor(sensor) == 0)
			*var = sensor;
	}
	return *var;
}

static void pm121_new_sensor(struct wf_sensor *sr)
{
	int all = 1;

	if (pm121_all_sensors_ok)
		return;

	all = pm121_register_sensor(sr, "cpu-temp",
				    &sensor_cpu_temp) && all;
	all = pm121_register_sensor(sr, "cpu-current",
				    &sensor_cpu_current) && all;
	all = pm121_register_sensor(sr, "cpu-voltage",
				    &sensor_cpu_voltage) && all;
	all = pm121_register_sensor(sr, "cpu-power",
				    &sensor_cpu_power) && all;
	all = pm121_register_sensor(sr, "hard-drive-temp",
				    &sensor_hard_drive_temp) && all;
	all = pm121_register_sensor(sr, "optical-drive-temp",
				    &sensor_optical_drive_temp) && all;
	all = pm121_register_sensor(sr, "incoming-air-temp",
				    &sensor_incoming_air_temp) && all;
	all = pm121_register_sensor(sr, "north-bridge-temp",
				    &sensor_north_bridge_temp) && all;
	all = pm121_register_sensor(sr, "gpu-temp",
				    &sensor_gpu_temp) && all;

	if (all)
		pm121_all_sensors_ok = 1;
}



static int pm121_notify(struct notifier_block *self,
			unsigned long event, void *data)
{
	switch (event) {
	case WF_EVENT_NEW_CONTROL:
		pr_debug("pm121: new control %s detected\n",
			 ((struct wf_control *)data)->name);
		pm121_new_control(data);
		break;
	case WF_EVENT_NEW_SENSOR:
		pr_debug("pm121: new sensor %s detected\n",
			 ((struct wf_sensor *)data)->name);
		pm121_new_sensor(data);
		break;
	case WF_EVENT_TICK:
		if (pm121_all_controls_ok && pm121_all_sensors_ok)
			pm121_tick();
		break;
	}

	return 0;
}

static struct notifier_block pm121_events = {
	.notifier_call	= pm121_notify,
};

static int pm121_init_pm(void)
{
	const struct smu_sdbp_header *hdr;

	hdr = smu_get_sdb_partition(SMU_SDB_SENSORTREE_ID, NULL);
	if (hdr != 0) {
		struct smu_sdbp_sensortree *st =
			(struct smu_sdbp_sensortree *)&hdr[1];
		pm121_mach_model = st->model_id;
	}

	pm121_connection = &pm121_connections[pm121_mach_model - 2];

	printk(KERN_INFO "pm121: Initializing for iMac G5 iSight model ID %d\n",
	       pm121_mach_model);

	return 0;
}


static int pm121_probe(struct platform_device *ddev)
{
	wf_register_client(&pm121_events);

	return 0;
}

static int pm121_remove(struct platform_device *ddev)
{
	wf_unregister_client(&pm121_events);
	return 0;
}

static struct platform_driver pm121_driver = {
	.probe = pm121_probe,
	.remove = pm121_remove,
	.driver = {
		.name = "windfarm",
		.bus = &platform_bus_type,
	},
};


static int __init pm121_init(void)
{
	int rc = -ENODEV;

	if (of_machine_is_compatible("PowerMac12,1"))
		rc = pm121_init_pm();

	if (rc == 0) {
		request_module("windfarm_smu_controls");
		request_module("windfarm_smu_sensors");
		request_module("windfarm_smu_sat");
		request_module("windfarm_lm75_sensor");
		request_module("windfarm_max6690_sensor");
		request_module("windfarm_cpufreq_clamp");
		platform_driver_register(&pm121_driver);
	}

	return rc;
}

static void __exit pm121_exit(void)
{

	platform_driver_unregister(&pm121_driver);
}


module_init(pm121_init);
module_exit(pm121_exit);

MODULE_AUTHOR("Étienne Bersac <bersace@gmail.com>");
MODULE_DESCRIPTION("Thermal control logic for iMac G5 (iSight)");
MODULE_LICENSE("GPL");