Kernel driver shtc1
===================

Supported chips:

  * Sensirion SHTC1

    Prefix: 'shtc1'

    Addresses scanned: none

    Datasheet: https://www.sensirion.com/file/datasheet_shtc1



  * Sensirion SHTW1

    Prefix: 'shtw1'

    Addresses scanned: none

    Datasheet: https://www.sensirion.com/file/datasheet_shtw1



  * Sensirion SHTC3

    Prefix: 'shtc3'

    Addresses scanned: none

    Datasheet: https://www.sensirion.com/file/datasheet_shtc3



Author:

  Johannes Winkelmann <johannes.winkelmann@sensirion.com>

Description
-----------

This driver implements support for the Sensirion SHTC1, SHTW1, and SHTC3
chips, a humidity and temperature sensor. Temperature is measured in degrees
celsius, relative humidity is expressed as a percentage.

The device communicates with the I2C protocol. All sensors are set to I2C
address 0x70. See Documentation/i2c/instantiating-devices.rst for methods to
instantiate the device.

There are two options configurable by means of shtc1_platform_data:

1. blocking (pull the I2C clock line down while performing the measurement) or
   non-blocking mode. Blocking mode will guarantee the fastest result but
   the I2C bus will be busy during that time. By default, non-blocking mode
   is used. Make sure clock-stretching works properly on your device if you
   want to use blocking mode.
2. high or low accuracy. High accuracy is used by default and using it is
   strongly recommended.

sysfs-Interface
---------------

temp1_input
	- temperature input
humidity1_input
	- humidity input