summaryrefslogtreecommitdiff
path: root/tools/perf/python/twatch.py
diff options
context:
space:
mode:
Diffstat (limited to 'tools/perf/python/twatch.py')
-rwxr-xr-xtools/perf/python/twatch.py81
1 files changed, 40 insertions, 41 deletions
diff --git a/tools/perf/python/twatch.py b/tools/perf/python/twatch.py
index 04f3db29b9bc..b0f1bf113162 100755
--- a/tools/perf/python/twatch.py
+++ b/tools/perf/python/twatch.py
@@ -1,5 +1,6 @@
#! /usr/bin/env python
# SPDX-License-Identifier: GPL-2.0-only
+"""Example to show how to enable a software event and track context switches."""
# -*- python -*-
# -*- coding: utf-8 -*-
# twatch - Experimental use of the perf python interface
@@ -9,53 +10,51 @@
import perf
def main(context_switch = 0, thread = -1):
- cpus = perf.cpu_map()
- threads = perf.thread_map(thread)
- evsel = perf.evsel(type = perf.TYPE_SOFTWARE,
- config = perf.COUNT_SW_DUMMY,
- task = 1, comm = 1, mmap = 0, freq = 0,
- wakeup_events = 1, watermark = 1,
- sample_id_all = 1, context_switch = context_switch,
- sample_type = perf.SAMPLE_PERIOD | perf.SAMPLE_TID | perf.SAMPLE_CPU)
-
- """What we want are just the PERF_RECORD_ lifetime events for threads,
- using the default, PERF_TYPE_HARDWARE + PERF_COUNT_HW_CYCLES & freq=1
- (the default), makes perf reenable irq_vectors:local_timer_entry, when
- disabling nohz, not good for some use cases where all we want is to get
- threads comes and goes... So use (perf.TYPE_SOFTWARE, perf_COUNT_SW_DUMMY,
- freq=0) instead."""
-
- evsel.open(cpus = cpus, threads = threads);
- evlist = perf.evlist(cpus, threads)
- evlist.add(evsel)
- evlist.mmap()
- while True:
- evlist.poll(timeout = -1)
- for cpu in cpus:
- event = evlist.read_on_cpu(cpu)
- if not event:
- continue
- print("cpu: {0}, pid: {1}, tid: {2} {3}".format(event.sample_cpu,
+ cpus = perf.cpu_map()
+ threads = perf.thread_map(thread)
+ evsel = perf.evsel(type = perf.TYPE_SOFTWARE,
+ config = perf.COUNT_SW_DUMMY,
+ task = 1, comm = 1, mmap = 0, freq = 0,
+ wakeup_events = 1, watermark = 1,
+ sample_id_all = 1, context_switch = context_switch,
+ sample_type = perf.SAMPLE_PERIOD | perf.SAMPLE_TID | perf.SAMPLE_CPU)
+
+ # What we want are just the PERF_RECORD_ lifetime events for threads,
+ # using the default, PERF_TYPE_HARDWARE + PERF_COUNT_HW_CYCLES & freq=1
+ # (the default), makes perf reenable irq_vectors:local_timer_entry, when
+ # disabling nohz, not good for some use cases where all we want is to get
+ # threads comes and goes... So use (perf.TYPE_SOFTWARE, perf_COUNT_SW_DUMMY,
+ # freq=0) instead.
+
+ evsel.open(cpus = cpus, threads = threads)
+ evlist = perf.evlist(cpus, threads)
+ evlist.add(evsel)
+ evlist.mmap()
+ while True:
+ evlist.poll(timeout = -1)
+ for cpu in cpus:
+ event = evlist.read_on_cpu(cpu)
+ if not event:
+ continue
+ print("cpu: {0}, pid: {1}, tid: {2} {3}".format(event.sample_cpu,
event.sample_pid,
event.sample_tid,
event))
if __name__ == '__main__':
- """
- To test the PERF_RECORD_SWITCH record, pick a pid and replace
- in the following line.
+ # To test the PERF_RECORD_SWITCH record, pick a pid and replace
+ # in the following line.
- Example output:
+ # Example output:
-cpu: 3, pid: 31463, tid: 31593 { type: context_switch, next_prev_pid: 31463, next_prev_tid: 31593, switch_out: 1 }
-cpu: 1, pid: 31463, tid: 31489 { type: context_switch, next_prev_pid: 31463, next_prev_tid: 31489, switch_out: 1 }
-cpu: 2, pid: 31463, tid: 31496 { type: context_switch, next_prev_pid: 31463, next_prev_tid: 31496, switch_out: 1 }
-cpu: 3, pid: 31463, tid: 31491 { type: context_switch, next_prev_pid: 31463, next_prev_tid: 31491, switch_out: 0 }
+ # cpu: 3, pid: 31463, tid: 31593 { type: context_switch, next_prev_pid: 31463, next_prev_tid: 31593, switch_out: 1 }
+ # cpu: 1, pid: 31463, tid: 31489 { type: context_switch, next_prev_pid: 31463, next_prev_tid: 31489, switch_out: 1 }
+ # cpu: 2, pid: 31463, tid: 31496 { type: context_switch, next_prev_pid: 31463, next_prev_tid: 31496, switch_out: 1 }
+ # cpu: 3, pid: 31463, tid: 31491 { type: context_switch, next_prev_pid: 31463, next_prev_tid: 31491, switch_out: 0 }
+ #
+ # It is possible as well to use event.misc & perf.PERF_RECORD_MISC_SWITCH_OUT
+ # to figure out if this is a context switch in or out of the monitored threads.
- It is possible as well to use event.misc & perf.PERF_RECORD_MISC_SWITCH_OUT
- to figure out if this is a context switch in or out of the monitored threads.
-
- If bored, please add command line option parsing support for these options :-)
- """
- # main(context_switch = 1, thread = 31463)
+ # If bored, please add command line option parsing support for these options :-)
+ # # main(context_switch = 1, thread = 31463)
main()